Dell OpenManage Server Administrator Version 6.5 Guida Utente Pagina 719

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 776
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 718
Traps 721
Cooling Device Traps
Cooling device traps monitor how well a fan is functioning.
Table 27-4. Cooling Device Traps
Trap ID Description Severity Cause
Cooling Device Normal
1102 Fan sensor returned to a
normal value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Information A fan sensor reading
on the specified
system returned to a
valid range after
crossing a warning
threshold. The
sensor location,
chassis location,
previous state, and
fan sensor value are
provided.
Cooling Device Warning
1103 Fan sensor detected a
warning value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Warning A fan sensor reading
in the specified
system exceeded a
warning threshold.
The sensor location,
chassis location,
previous state, and
fan sensor value are
provided.
book.book Page 721 Monday, March 14, 2011 3:01 PM
Vedere la pagina 718
1 2 ... 714 715 716 717 718 719 720 721 722 723 724 ... 775 776

Commenti su questo manuale

Nessun commento