Dell PowerEdge FX2/FX2s Manuale Utente

Navigare online o scaricare Manuale Utente per Hardware del computer Dell PowerEdge FX2/FX2s. Dell PowerEdge FX2/FX2s User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 462
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti

Sommario

Pagina 1 - 9.6.(0.0)

Dell PowerEdge FN I/O AggregatorCommand Line Reference Guide9.6.(0.0)

Pagina 2 - Notes, Cautions, and Warnings

TACACS+ Commands... 226tacacs-serve

Pagina 3 - Contents

PP (KB) (KB) (KB) (KB)----------------------------------------------------------------------

Pagina 4

show dcbDisplays the data center bridging status, the number of PFC-enabled ports, and the number of PFC-enabled queues.Syntaxshow dcb [stack-unit uni

Pagina 5

Field DescriptionPort-Role Configured DCBX port role: auto-upstream or auto-downstream.DCBX Operational StatusOperational status (enabled or disabled)

Pagina 6

Field DescriptionPeer DCBX Status: Sequence NumberSequence number transmitted in Control TLVs received from the peer device.Peer DCBX Status: Acknowle

Pagina 7

ExampleDell#show int te 0/2 dcbx detailE-ETS Configuration TLV enabled e-ETS Configuration TLV disabledR-ETS Recommendation TLV enabled

Pagina 8

Command ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationTo clear ETS TLV counters, use the clea

Pagina 9

Field DescriptionReason Reason displayed when the DCBx operational status for ETS on a port is down.State Machine TypeType of state machine used for D

Pagina 10

Remote Parameters :-------------------Remote is disabledLocal Parameters :------------------Local is enabledTC-grp Priority# Bandwidth TSA-

Pagina 11

Field DescriptionInterface Interface type with stack-unit and port number.Admin mode is on, Admin is enabledPFC mode: on or off. Priority list: list o

Pagina 12

Field DescriptionApplication Priority TLV: Local ISCSI Priority MapPriority bitmap used by the local DCBX port in ISCSI advertisements in application

Pagina 13

show system stack-unit iom-mode...253show system stack-u

Pagina 14

Remote ISCSI PriorityMap is 0x8 0 Input TLV pkts, 1 Output TLV pkts, 0 Error pkts, 0 Pause Tx pkts, 0 PauseRx pkts 0 Input Appln Priority TLV pkts,

Pagina 15

Command Modes• EXEC• EXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationUse the show qos dcb-map comman

Pagina 16

8Dynamic Host Configuration ProtocolDynamic host configuration protocol (DHCP) is an application layer protocol that dynamically assigns IP addresses

Pagina 17 - About this Guide

Command ModesEXEC PrivilegeDefault NoneCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.debug ip dhcp client eventsEnable the displa

Pagina 18 - Conventions

Parametersinterface type slot/portDisplay log messages for DHCP packets sent and received on the specified interface.• For the management interface on

Pagina 19 - Before You Start

Parametersinterface type slot/port• For the management interface on the stack-unit, enter the keyword management ethernet followed by slot/port inform

Pagina 20 - Default Settings

To display the currently configure dynamic IP address and lease time, enter the show ip dhcp lease command.show ip dhcp client statisticsDisplays DHCP

Pagina 21 - FCoE Connectivity

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.117

Pagina 22 - Link Tracking

9FIP SnoopingIn a converged Ethernet network, an Aggregator can operate as an intermediate Ethernet bridge to snoop on Fibre Channel over Ethernet Ini

Pagina 23 - Where to Go From Here

virtual-link-maintenance | vlan-discovery } { port-channel | tengigabitethernet } } | tx ]Parametersall Enable all the debug options.acl Enable for AC

Pagina 24 - CLI Basics

Data Center Bridging (DCB)... 295advertise d

Pagina 25 - Navigating the CLI

show fip-snooping configDisplays the FIP snooping status and configured FC-MAP values.Syntaxshow fip-snooping configCommand Modes• EXEC• EXEC Privileg

Pagina 26 - Obtaining Help

ExampleDell# show fip-snooping enodeEnode MAC Enode Interface FCF MAC VLAN FC-ID---------

Pagina 27 - Filtering show Commands

show fip-snooping sessionsDisplays information on FIP-snooped sessions on all VLANs or a specified VLAN, including the ENode interface and MAC address

Pagina 28 - Command Modes

show fip-snooping statisticsDisplays statistics on the FIP packets snooped on all interfaces, including VLANs, physical ports, and port channels.Synta

Pagina 29 - LINE Mode

Field DescriptionNumber of FLOGONumber of FIP-snooped FLOGO frames received on the interfaceNumber of ENode Keep AlivesNumber of FIP-snooped ENode kee

Pagina 30 - PROTOCOL LLDP Mode

ExampleDell# show fip-snooping statistics interface vlan 100Number of Vlan Requests :0Number of Vlan Notifications

Pagina 31 - File Management

Number of FDISC Accepts :16Number of FDISC Rejects :0Number of FLOGO Accepts

Pagina 32

*1 - - - -1002 0X0EFC00 1 1 1127

Pagina 33

10HTTP Copy via CLIThis chapter describes the HTTP Copy via CLI command in the Dell Networking OS.copy httpCopy one file to another location. Dell Net

Pagina 34

11Internet Group Management Protocol (IGMP)The Dell Networking OS supports IGMP snooping version 2 and 3 on all Dell Networking systems.IGMP CommandsT

Pagina 35

pwd... 327r

Pagina 36

interface (OPTIONAL) Enter the interface type and slot/port information:For a VLAN interface enter the keyword vlan followed by a number from 1 to 409

Pagina 37

Command ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.show ip igmp groupsView the IGMP groups.Syntaxshow ip igm

Pagina 38

Interface Lists the interface type, slot and port number.Mode Displays the IGMP version used.Uptime Displays the amount of time the group has been ope

Pagina 39

IGMP Snooping query interval is 60 secondsIGMP Snooping querier timeout is 125 secondsIGMP Snooping last member query response interval is 1000 msIGMP

Pagina 40

12InterfacesThis chapter defines interface commands and is divided into the following sections:• Port Interface Commands• Port Channel Commands• Time

Pagina 41

Port Channel CommandsA Link Aggregation Group (LAG) is a group of links that appear to a MAC client as if they were a single link according to IEEE 80

Pagina 42

• name• show config (from INTERFACE VLAN mode)• show vlan• vlan tagged• vlan untaggedauto vlanChange the port to auto or admin vlan mode (enable or di

Pagina 43

• For a Port Channel interface, enter the keyword port-channel followed by a number. Range: 1-128Command ModesEXEC PrivilegeCommand HistoryVersion 9.4

Pagina 44

To reset the default VLAN ID, use the no default vlan-id command.Defaults noneCommand ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on t

Pagina 45

interface rangeThis command permits configuration of a range of interfaces to which subsequent commands are applied (bulk configuration). Using the in

Pagina 46

channel-member...358interface por

Pagina 47

Example-Bulk Configuration Warning MessageDell(conf)#interface range tengig 0/1 - 2 , tengig 0/4 , tengig 0/7, fa 0/0% Warning: Non-existing ports (no

Pagina 48 - Control and Monitoring

Parametersdef-vlan-id Enter 1 for the default VLAN.Defaults Not configuredCommand ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the F

Pagina 49

Command Modes• EXEC• EXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThe delta column displays chang

Pagina 50

Over 1023B packets: 2781 0 pps 0 Error statistics: Input underruns: 0 0 pps 0 Input giants: 0 0 pps

Pagina 51

To convert the interfaces 9 and 10 from Ethernet to Fibre Channel mode, use the no stack-unit unit number port-group 0 portmode ethernet.Parameterssta

Pagina 52

negotiation autoEnable auto-negotiation on an interface.Syntaxnegotiation autoTo disable auto-negotiation, enter no negotiation auto command.Defaults

Pagina 53

• auto-negotiation disabled speed 100• auto-negotiation enabled speed 100• auto-negotiation disabled speed 100Link Status Between Port 1 and Port 2• U

Pagina 54

ExampleDell(conf)#interface range tengigabitethernet 0/1 - 2Dell(conf-if-range-te-0/1-2)#show config!interface TenGigabitEthernet 0/1 no ip address

Pagina 55

show interfacesDisplays information on a specific physical interface or virtual interface.Syntaxshow interfaces interfaceParametersinterface Enter one

Pagina 56

Line DescriptionHardware is... Displays the interface hardware information and its assigned MAC address.Interface index... Displays the interface inde

Pagina 57

show interfaces status... 392show qos dcb

Pagina 58

Line DescriptionOutput Statistics: Displays output statistics sent out of the interface including:• Number of packets, bytes, and underruns out of the

Pagina 59

Output 4627 packets, 814226 bytes, 0 multicastOutput 0 errors, 0 invalid protocolRelated Commandsshow interfaces configured — Displays any interface w

Pagina 60

0 packets, 0 bytes0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte pkts0 Multicas

Pagina 61

Field DescriptionInterface Displays the type of interface and associated slot and port number.OK? Indicates if the hardware is functioning properly.St

Pagina 62

Usage InformationThe following describes the show interfaces port-channel command shown in the following example.Field DescriptionPort-Channel 1... Di

Pagina 63

Example (EtherScale)Dell#show interfaces port-channelPort-channel 1 is down, line protocol is downHardware address is 00:1e:c9:f1:00:05, Current addre

Pagina 64

Field Description• In Layer 3 port channels, the primary port is not indicated.ExampleDell#show int po 1 briefCodes: L - LACP Port-channelLAG Mode Sta

Pagina 65

0 packets, 0 bytes, 0 underruns0 64-byte pkts, 0 over 64-byte pkts, 0 over 127-byte pkts0 over 255-byte pkts, 0 over 511-byte pkts, 0 over 1023-byte p

Pagina 66

Te 0/12 Up 10000 Mbit Full --Dell#show interfaces switchportDisplay only virtual and physical interfaces in Layer 2 mode. This com

Pagina 67

802.1QTagged: HybridIO-AGG port mode: Auto VLANs enabledVlan membership:Q VlansU 1T 2-4094Native VlanId: 1.Name: TenGigabitEthernet 0/2802.1QTagged: H

Pagina 68

downstream disable links... 450show running-co

Pagina 69

Status DefinitionLength: 93 (+/- 1) meters, Status: OpenAn opening is detected on the cable. The location, in this Example is 93 meters. The open is a

Pagina 70

Usage InformationThe following describes the show vlan command information given in the following exampleColumn Heading Description(Column 1 — no head

Pagina 71

x - Dot1x untagged, X - Dot1x taggedG - GVRP tagged, M - Vlan-stackNUM Status Description Q Ports222 Inactive U TenGig 1/22Dell(conf-if-vl-222)#Dell#R

Pagina 72

speed (for 1000/10000 interfaces)Set the speed for 1000/10000 Base-T Ethernet interfaces. Both sides of a link must be set to the same speed (1000/100

Pagina 73

Parametersinterface Enter the keyword TenGigabitEthernet followed by the slot/port information for the 100/1000/10GBase-T Ethernet interface.Defaults

Pagina 74

For example, if port 0/1-32 is an untagged member of VLAN 2 and port 0/41 is an untagged member of VLAN 3, the resulting LAG consisting of the two por

Pagina 75

Tagged interfaces can belong to multiple VLANs, while untagged interfaces can only belong to one VLAN at a time.When two or more ports configured for

Pagina 76

13IPv4 RoutingThe aggregator supports both IPv4 and IPv6 routing and these are used only for the management purpose.This chapter describes the IPv4 re

Pagina 77

Defaults Debug disabledCommand ModeEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.ExampleFTOS#debug ip dhcp00:12:21

Pagina 78

• For the management interface, enter the keyword ManagementEthernet then the slot/port information. The slot range is 0 and the port range is 0.• For

Pagina 79

1About this GuideThis book provides information about the Dell Networking OS command line interface (CLI) on the Dell PowerEdge FN I/O Aggregator.This

Pagina 80

interface For a VLAN, enter the keyword vlan followed by a number from 1 to 4094.distance (OPTIONAL) Enter a number as the distance metric assigned t

Pagina 81

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationWhen a static route (or a protocol route) overlaps with Management

Pagina 82

Row Heading DescriptionCPU Lists which CPU the entries are stored on.ExampleDell#show arp Protocol Address Age(min) Hardware Address

Pagina 83

3 0 3 CPDell#show ip interfaceView IP-related information on all interfaces.Syntaxshow ip interface [interface | b

Pagina 84

Lines DescriptionInbound access... Displays the name of the any configured incoming access list. If none is configured, the phrase “not set” is displa

Pagina 85

TenGigabitEthernet 0/8 unassigned NO None up downTenGigabitEthernet 0/9 unassigned NO None up downshow ip management-routeView the IP ad

Pagina 86

pipe-numberEnter the number of the Port-Pipe number. The range is from 0 to 0.ip-address mask [longer-prefix](OPTIONAL) Enter the IP address and mask

Pagina 87

Field Description• CP = control processor• Fo= 40 Gigabit Ethernet interface• Te = 10 Gigabit Ethernet interfaceExampleDell#show ip multicast-cam stac

Pagina 88

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThe following describes the show ip route all command in the follo

Pagina 89 - [no] default gateway

Last Change ----------- ------- ----------- -----------*S 0.0.0.0/0 via 10.10.91.9, Te 1/2 1/0 3d2hDell#

Pagina 90

AudienceThis book is intended for system administrators who are responsible for configuring or maintaining networks. This guide assumes that you are k

Pagina 91

Field Description0 packets after closeDisplays the number of packet received after the TCP connection was closed.0 window probe packets...Displays the

Pagina 92

7 control packets6674 data packets (152822 bytes)12 data packets (1222 bytes) retransmitted85 ack only packets (5677 delayed)0 window probe packets, 0

Pagina 93

14iSCSI OptimizationInternet small computer system interface (iSCSI) optimization enables quality-of-service (QoS) treatment for iSCSI storage traffic

Pagina 94

• show iscsi sessions detailed — displays detailed information on active iSCSI sessions on the switch.show iscsi sessionsDisplay information on active

Pagina 95

• EXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.ExampleDell# show iscsi sessions detailedSession 0 :---------------

Pagina 96

15Isolated NetworksThis chapter describes the isolated networks commands in the Dell Networking OS.io-aggregator isolated-network vlanEnable the isola

Pagina 97

Parametersisolated-networksSpecify an isolated network to be configuredvlan vlan-range Enter the keyword vlan followed by the member VLANs using VLAN

Pagina 98

16Link Aggregation Control Protocol (LACP)This chapter contains commands for Dell Networking’s implementation of the link aggregation control protocol

Pagina 99

Command ModesEXECEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Related Commandsshow lacp — displays the LACP config

Pagina 100

io-aggregator auto-lag enableEnable auto-lag globally on the server facing portsSyntaxio-aggregator auto-lag enableTo disable the auto-lag, use the no

Pagina 101

2Before You StartBy following the instructions in the Dell PowerEdge FN I/O Aggregator Getting Started Guide that is shipped with the product, you ins

Pagina 102

show lacpDisplays the LACP matrix.Syntaxshow lacp port-channel-number [sys-id | counters]Parametersport-channel-numberEnter a port-channel number:The

Pagina 103

TenGig 0/1 200 200 0 0 0 0Dell#Related Commandsclear lacp counters — Clears the LACP counters.show interfaces port-channel —

Pagina 104

Command ModesEXECCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationBecause this command calculates based on a Layer

Pagina 105

Field DescriptionAlarm State Indicates whether an alarm is generated if overutilization of the port channel occurred. Possible values are Active and I

Pagina 106

17Layer 2This chapter describes commands to configure Layer 2 features.This chapter contains the following sections:• MAC Addressing Commands• Virtual

Pagina 107

• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet followed by the slot/port information.vlan vlan-id Enter the keyword vlan

Pagina 108

Parametersstack-unit unit_number(REQUIRED) Enter the keyword stack-unit followed by a stack member number to select the stack unit for which to gather

Pagina 109

18Link Layer Discovery Protocol (LLDP)The link layer discovery protocol (LLDP) advertises connectivity and management from the local station to the ad

Pagina 110

debug lldp interfaceEnable LLDP debugging to display timer events, neighbor additions or deletions, and other information about incoming and outgoing

Pagina 111

protocol lldp (Configuration)Enable LLDP globally on the switch.Syntaxprotocol lldpTo disable LLDP globally on the chassis, use the no protocol lldp c

Pagina 112

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Pagina 113

Dell(conf)#stack-unit 0 iom-mode programmable-muxSelect this mode to configure PMUX mode CLI commands.For more information on the PMUX mode, refer to

Pagina 114

Parametersinterface (OPTIONAL) Enter the following keywords and slot/port or number information:• For a 10-Gigabit Ethernet interface, enter the keywo

Pagina 115

Total number of Table Age Outs: 0Dell#201

Pagina 116

19Port MonitoringThe port monitoring feature allows you to monitor network traffic by forwarding a copy of each incoming or outgoing packet from one p

Pagina 117 - Command

descriptionEnter a description of this monitoring session.Syntaxdescription {description}To remove the description, use the no description {descriptio

Pagina 118 - FIP Snooping

Related Commandshow monitor session — Displays the monitor session.show running-config monitor session — Displays the running configuration of a monit

Pagina 119

ExampleDell#show monitor session 5SessionID Source Destination Direction Mode Type--------- ------ ----------- --------- ---- ---- 5

Pagina 120

show monitor session — displays a monitor session.source (port monitoring)Configure a port monitor source.Syntaxsource interface destination interface

Pagina 121

20Quality of Service (QoS)The Dell Networking OS commands for quality of service (QoS) include traffic conditioning and congestion control.This chapte

Pagina 122

Field DescriptionState Complete: All mandatory DCB parameters are correctly configured. In progress: The DCB map configuration is not complete. Some m

Pagina 123

21SecurityThis chapter describes various types of security commands in the Dell Networking OS, in the following sections:The commands are listed in th

Pagina 124

• Fibre Channel over Ethernet (FCoE) connectivity• FCoE Initiation Protocol (FIP) snooping• Hybrid ports: Ports are administratively up and auto-confi

Pagina 125

commands levelEnter the keyword command then a privilege level for accounting of commands executed at that privilege level.name | default Enter one of

Pagina 126

To permit accounting records to users with user name value of NULL, use the no aaa accounting suppress null-username command.Defaults Accounting recor

Pagina 127

Undo a configuration with the no aaa authorization commands {level|{name|default} {local | tacacs+ | none} command.Parameterscommands levelEnter the k

Pagina 128 - HTTP Copy via CLI

Disable authorization checking for CONFIGURATION level commands using the no aaa authorization config-commands command.Defaults Enabled when you confi

Pagina 129 - IGMP Commands

Defaults noneCommand ModesCONFIGURATIONCommand HistoryThis guide is platform-specific. For command information about other platforms, refer to the rel

Pagina 130

Authentication and Password CommandsThis section contains the commands that control the management access to the system.aaa authentication enableConfi

Pagina 131

reachable, but the server key is invalid, Dell Networking OS proceeds to the next authentication method. The TACACS+ is incorrect, but the user is sti

Pagina 132

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationBy default, the locally configured username password is used. If y

Pagina 133

Defaults No banner is displayed.Command ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationAfter en

Pagina 134 - Interfaces

line Enter a text string for your text banner message ending the message with your delineator. The delineator is a percent character (%). Range: maxim

Pagina 135 - Virtual LAN (VLAN) Commands

storm control on interfaces connected to an iSCSI equallogic (EQL) storage device, are applied automatically.CLI configuration is necessary only when

Pagina 136

Defaults Disabled.Command ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.debug tacacs+To assist with troublesho

Pagina 137

Parametersinterface Enter the following keywords and slot/port or number information:• For a Port Channel interface, enter the keywords port-channel t

Pagina 138

To use the local user/password database for login authentication, use the no login authentication command.Parametersmethod-list-nameEnter the keywords

Pagina 139

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.radius-server hostConfigure a RADIUS server host.Syntaxradius-server host {hostname

Pagina 140

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationTo configure any number of RADIUS server hosts for each server hos

Pagina 141

radius-server timeoutTo reply to a request, configure the amount of time the RADIUS client (the switch) waits for a RADIUS host server .Syntaxradius-s

Pagina 142

Usage InformationThe key configured on the switch must match the key configured on the RADIUS server daemon.If you configure the key parameter in the

Pagina 143

tacacs-server hostSpecify a TACACS+ host.Syntaxtacacs-server host {hostname | ipv4-address | ipv6-address} [port number] [timeout seconds] [key key]Pa

Pagina 144

To delete a key, use the no tacacs-server key key command.Parametersencryption-type(OPTIONAL) Enter either zero (0) or 7 as the encryption type for th

Pagina 145

start-stop Enter the keywords start-stop to send a “start accounting” notice at the beginning of the requested event and a “stop accounting” notice at

Pagina 146

Server-Facing LAGsThe tagged VLAN membership of a server-facing LAG is automatically configured based on the server-facing ports that are members of t

Pagina 147

ParameterssecondsEnter a number of seconds the software waits before logging you out. The range is:• VTY: the range is from 1 to 30 seconds, the defau

Pagina 148

password Enter a text string, up to 32 characters long, as the clear text password.Defaults No password is configured. level = 15.Command ModesCONFIGU

Pagina 149

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationOnly Dell Networking Technical Support staff use this command.serv

Pagina 150

RSA Authentication : disabled.Dell#Related Commandsshow ip ssh client-pub-keys — displays the client-public keys.show ip ssh client-pub-keysDi

Pagina 151

AAAAB3NzaC1yc2EAAAABIwAAAIEAyB17l4gFp4r2DRHIvMc1VZd0Sg5GQxRV1y1X1JOMeO6Nd0WuYyzrQMM4qJAoBwtneOXfLBcHF3V2hcMIqaZN+CRCnw/zCMlnCf0+qVTd1oofsea5r09kS0xTp0

Pagina 152

sshOpen an SSH connection specifying the host name, username, port number and version of the SSH client.Dell Networking OS supports both inbound and o

Pagina 153

nopassword Enter the keyword nopassword to specify that the user should not enter a password.password Enter the keyword password followed by the encry

Pagina 154

22Simple Network Management Protocol (SNMP) and SyslogThis chapter contains commands to configure and monitor the simple network management protocol (

Pagina 155

• show logging• terminal monitorclear loggingClear the messages in the logging buffer.Syntaxclear loggingDefaults noneCommand ModesEXEC PrivilegeComma

Pagina 156

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationWhen you decrease the buffer size, all messages stored in the buff

Pagina 157

3CLI BasicsThis chapter describes the command line interface (CLI) structure and command modes. The Dell operating system commands are in a text-based

Pagina 158

logging hostnameConfigure an IP address or host name of a Syslog server where logging messages are sent. Multiple logging servers of both IPv4 and/or

Pagina 159

logging source-interfaceSpecify that the IP address of an interface is the source IP address of Syslog packets sent to the Syslog server.Syntaxlogging

Pagina 160

summary (OPTIONAL) Enter the keyword summary to view a table showing the number of messages per type and per slot.driverlog (OPTIONAL) Enter the keywo

Pagina 161

Enable password authentication success on consoleJul 31 14:26:17: %STKUNIT1-M:CP %SEC-4-ENABLE_PASSW_NOT_CONFIGURED:Enable password is required for au

Pagina 162

Command Modes• EXEC• EXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.ExampleDell#show snmp 32685 SNMP packets input

Pagina 163

show snmp groupDisplay the group name, security model, status, and storage type of each group.Syntaxshow snmp groupCommand Modes• EXEC• EXEC Privilege

Pagina 164

snmp-server communityConfigure a new community string access for SNMPv1 and v2.Syntaxsnmp-server community community-name {ro}To remove access to a co

Pagina 165

23Storm ControlThe Dell Networking OS storm control feature allows you to limit or suppress traffic during a traffic storm.NOTE: When iSCSI storage de

Pagina 166

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.ExampleDell#show io-aggregator broadcast storm-control statusStorm-Control EnabledB

Pagina 167 - IPv4 Routing

24Stacking CommandsStacking is supported on the FN410S and FN410T cards with ports 9 and 10 as the stack ports. Stacking is limited to six Aggregators

Pagina 168

User "Irene" on line vty3 ( 123.12.1.321 )Dell#confWhen another user enters CONFIGURATION mode, the Dell Networking OS sends a message simil

Pagina 169

This command is used to reset the stack-unit. The master unit can also be power cycled using this command.reset stack-unitReset any designated stack m

Pagina 170

01:02:00: %STKUNIT0-M:CP %IFMGR-1-DEL_PORT: Removed port: Te 1/1-32,41-5601:02:00: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 1 down - reset01

Pagina 171

Field DescriptionInterface The unit/port ID of the connected stack port on this unit.Link Speed Link Speed of the stack port (10) in Gb/s.Admin Status

Pagina 172

stack-unit iom-modeToggle the FN I/O Aggregator operating mode between programmable multiplex, stand-alone, stack, and VLT modes.Syntaxstack-unit <

Pagina 173

Parametersunit number <0–5>Enter the number of the member stack unit. The range is from 0 to 5.Command ModesEXEC PrivilegeCommand HistoryVersion

Pagina 174

Configured stack groups in stack-unit 0Dell#show system stack-unit 0 stack-groupStack group Ports------------------------------------0 0/91

Pagina 175

stack-unit renumberChange the stack member ID of any stack member or a stand-alone unit.Syntaxstack-unit 0-5 renumber 0-5Parameters0-5 The first insta

Pagina 176

25System TimeThe commands in this chapter configure time values on the system, either using the Dell Networking OS, the hardware, or using the network

Pagina 177

show clockDisplays the current clock settings.Syntaxshow clock [detail]Parametersdetail (OPTIONAL) Enter the keyword detail to view the source informa

Pagina 178

year Enter a four-digit number as the year. The range is from 1993 to 2035.Defaults Not configured.Command ModesEXEC PrivilegeCommand HistoryVersion 9

Pagina 179

Obtaining HelpAs soon as you are in a command mode there are several ways to access help.To obtain a list of keywords at any command mode:Type a ? at

Pagina 180

end-day Enter the number of the day. The range is from 1 to 31. You can enter the name of a month to change the order of the display to time day month

Pagina 181

• week-number: Enter a number from 1 to 4 as the number of the week in the month to start daylight saving time.• first: Enter this keyword to start da

Pagina 182

clock timezoneConfigure a timezone for the switch.Syntaxclock timezone timezone-name offsetTo delete a timezone configuration, use the no clock timezo

Pagina 183

26Uplink Failure Detection (UFD)Uplink failure detection (UFD) provides detection of the loss of upstream connectivity and, if you use this with netwo

Pagina 184

To disable upstream-link tracking without deleting the uplink-state group, use the no enable command.group-id Enables debugging on the specified uplin

Pagina 185 - Isolated Networks

27Virtual Link Trunking (VLT)Virtual link trunking (VLT) allows physical links between two chassis to appear as a single virtual link to the network c

Pagina 186

show vlt briefDisplay brief status information about VLT domains currently configured on the switch.Syntaxshow vlt brief Default Not configured.Comman

Pagina 187

128 128 UP UP 1000Dell#show vlt roleDisplay the VLT peer status, role of the local VLT switch, VLT system MAC

Pagina 188

VLT MAC Statistics--------------------L2 Info Pkts sent:16, L2 Mac-sync Pkts Sent:25L2 Info Pkts Rcvd:15, L2 Mac-sync Pkts Rcvd:24L2 Reg Request sent:

Pagina 189

Parametersunit number <0-5>Enter the number of the member stack unit. The range is from 0 to 5. The default is 0.vlt Enable virtual link trunkin

Pagina 190

Key Combination ActionCNTL-K Deletes all the characters from the cursor to the end of the command line.CNTL-L Re-enters the previous command.CNTL-N Re

Pagina 191

28Debugging and DiagnosticsThis chapter contains the following sections:• Offline Diagnostic Commands• Hardware Commands Offline Diagnostic CommandsTh

Pagina 192

clear hardware stack-unitClear statistics from selected hardware components.Syntaxclear hardware stack-unit 0–5 {counters | unit 0–1 counters | cpu da

Pagina 193

level0 Enter the keyword level0 to run Level 0 diagnostics. Level 0 diagnostics check for the presence of various components and perform essential pat

Pagina 194 - MAC Addressing Commands

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.offline stack-unitPlace a stack unit in the offline state.Syntaxoffline stack-unit

Pagina 195

stack-unit unit-idEnter the keyword stack-unit followed by the unit-id to display information on a specific stack member. The range is from 0 to 5.det

Pagina 196

Example 3 (show diag testcase stack-unit Command)Dell#show diag testcase stack-unit 0 **************************** Blade IOM Diagnostics Test ********

Pagina 197

123 MGMTPHYACCESSTEST Level1 124 SDFLASHFILECOPYSTRESSTEST Level1

Pagina 198

show hardware stack-unitDisplay the data plane or management plane input and output statistics of the designated component of the designated stack mem

Pagina 199

NOTE: You can identify stack port numbers by physical inspection of the rear modules. The numbering is the same as for the 10G ports. You can also ins

Pagina 200

txPkt(COS4) :0 txPkt(COS5) :0 txPkt(COS6) :0 txPkt(COS7) :0 txPkt(COS8) :0 txPkt(COS9) :0

Pagina 201

NOTE: The Dell Networking OS accepts a space before or after the pipe, no space before or after the pipe, or any combination. For example: Dell#comman

Pagina 202 - Port Monitoring

Example (drop counters)Dell#show hardware stack-unit 0 drops unit 0 port 27 --- Ingress Drops ---Ingress Drops : 0IBP CBP Full Drops

Pagina 203

Example (register)Dell#show hardware stack-unit 0 unit 0 register0x0f180d34 ALTERNATE_EMIRROR_BITMAP_PARITY_CONTROL.ipipe0 = 0x000000010x0f180d35 ALTE

Pagina 204

Link Status of all the ports in the Device - 0The linkStatus of Front End Port 42 is TRUE The linkStatus of Front End Port 43 is TRUE The linkStatus o

Pagina 205

show hardware system-flowDisplay Layer 2 ACL or QoS data for the selected stack member and stack member port-pipe.Syntaxshow hardware system-flow laye

Pagina 206

708 VLT STP BPDUs Tunneled 0 707 VLT IGMP Sync Frames 0 706

Pagina 207 - Quality of Service (QoS)

492 224.0.0.x 24 491 224.0.1.1 0 490

Pagina 208

action={act=CosQCpuNew, param0=7(0x07), param1=0(0x00)}, action={act=CopyToCpu, param0=0(0x00), param1=0(0x00)}, action={a

Pagina 209 - Security

, 0x00 action={act=Drop, param0=0(0x00), param1=0(0x00)}, action={act=CosQCpuNew, param0=6(0x06), param1=0(0x00)},

Pagina 210

29NPIV Proxy GatewayThe N-port identifier virtualization (NPIV) Proxy Gateway (NPG) feature provides FCoE-FC bridging capability on the FN I/O Aggrega

Pagina 211

The following table describes the show fcoe-map brief output shown in the example below.Field DescriptionFabric-Name Name of a SAN fabric.Fabric ID Th

Pagina 212

NOTE: Each mode prompt is preceded by the host name.EXEC Privilege ModeThe enable command accesses EXEC Privilege mode. If an administrator has config

Pagina 213

Field DescriptionFCF Priority The priority used by a server to select an upstream FCoE forwarder.Config-State Indicates whether the configured FCoE an

Pagina 214

Command Modes• EXEC• EXEC PrivilegeCommand HistoryVersion 9.6(0.0) Supported on the FN2210S Aggregator.Version 9.3(0.0) Introduced on the M I/O Aggreg

Pagina 215

Field DescriptionENode-WWPN Worldwide port name (WWPN) of a server CNA port.FCoE-Vlan VLAN ID of the dedicated VLAN used to transmit FCoE traffic to a

Pagina 216

Field DescriptionFCF MAC Fibre Channel forwarder MAC: MAC address of FN I/O Aggregator Switch with the FC Flex IO module FCF interface.Fabric Intf Fab

Pagina 217

FCoE MAC : 0e:fc:03:01:02:02FC-ID : 01:02:01LoginMethod : FDISCSecs : 5593Status : LOGGED_INRelated Comm

Pagina 218

30PMUX Mode of the I/O AggregatorThis chapter describes the various CLI commands applicable in PMUX mode.Data Center Bridging (DCB)Data center bridgin

Pagina 219

advertise dcbx-tlvOn a DCBX port with a manual role, configure the PFC and ETS TLVs advertised to DCBX peers.Syntaxadvertise dcbx-tlv {ets-conf | ets-

Pagina 220

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.clear ets countersClear ETS TLV counters.Syntaxclear ets counters [tengigabitethern

Pagina 221

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (PMUX) mode only.Usage InformationDC

Pagina 222 - RADIUS Commands

Command ModesCONFIGURATIONINTERFACECommand HistoryVersion 9.6(0.0) Supported on the FN I/O AggregatorVersion 9.3(0.0) Introduced on the FC Flex IO mod

Pagina 223

Contents1 About this Guide...17Objectives...

Pagina 224

1. Verify that you are logged in to CONFIGURATION mode.2. Enter the line command. Include the keywords console or vty and their line number available

Pagina 225

Usage InformationThe dcb-map stack-unit all stack-ports all command overwrites any previous DCB maps applied to stack ports.Related Commandsdcb-map –

Pagina 226 - TACACS+ Commands

To remove the DCBX version, use the dcbx version {auto | cee | cin | ieee-v2.5} command.Parametersauto | cee | cin | ieee-v2.5Enter the DCBX version t

Pagina 227

• tlv: enables traces for DCBX TLVs.Defaults noneCommand ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This c

Pagina 228 - TACACS+ Accounting

FCoE network by providing FCoE-enabled servers and switches with the necessary parameters to log in to a SAN fabric.On an FN2210S Aggregator a with th

Pagina 229

Parameterspriority-bitmap Enter the priority-bitmap range. The range is from 1 to FF.Defaults 0x10Command ModesPROTOCOL LLDPCommand HistoryVersion 9.4

Pagina 230 - SSH Server and SCP Commands

consists of 802.1p priority values that are grouped together for similar bandwidth allocation and scheduling, and that share latency and loss requirem

Pagina 231

dot1p5_group-numdot1p6_group-numdot1p7_group-numDefaults NoneCommand ModesDCB MAPCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Us

Pagina 232

Command ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (PMUX) mo

Pagina 233

Field DescriptionConfiguration SourceSpecifies whether the port serves as the DCBX configuration source on the switch: true (yes) or false (no).Local

Pagina 234

Field DescriptionTotal DCBX Frames transmittedNumber of DCBX frames sent from the local port.Total DCBX Frames receivedNumber of DCBX frames received

Pagina 235

4File ManagementThis chapter contains commands needed to manage the configuration files and includes other file management commands.The commands in th

Pagina 236

show interface etsDisplays the ETS configuration applied to egress traffic on an interface, including priority groups with priorities and bandwidth al

Pagina 237 - (SNMP) and Syslog

Field DescriptionLocal Parameters ETS configuration on local port, including admin mode (enabled when a valid TLV is received from a peer), priority g

Pagina 238

7 0% ETSPriority# Bandwidth TSA0 13% ETS1 13% ETS2

Pagina 239

6 12% ETS7 12% ETSRemote Parameters:-------------------Remote is disabledLocal Parameters :---

Pagina 240

Usage InformationTo clear the PFC TLV counters, use the clear pfc counters interface port-type slot/port command.The following describes the show inte

Pagina 241

Field DescriptionApplication Priority TLV: SCSI TLV Tx StatusStatus of ISCSI advertisements in application priority TLVs from the local DCBX port: ena

Pagina 242

Remote ISCSI PriorityMap is 0x8Dell# show interfaces tengigabitethernet 0/4 pfc detail Interface TenGigabitEthernet 0/4 Admin mode is on Admin is

Pagina 243

show qos dcb-mapDisplay the DCB parameters configured in a specified DCB map.Syntaxshow qos dcb-map map-nameParametersmap-name Displays the PFC and ET

Pagina 244

Related Commandsdcb-map — creates a DCB map to configure PFC and ETS parameters and applies the PFC and ETS settings on Ethernet ports.show stack-unit

Pagina 245

4 - -5 - -6 - -7 - -8

Pagina 246

primary Enter the keyword primary to set the primary image path for the system.secondary Enter the keyword secondary to set the secondary image path f

Pagina 247 - Storm Control

clear ip dhcp client statisticsDisplays DHCP client statistics, including the number of DHCP messages sent and received on an interface.Syntaxclear ip

Pagina 248

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.ip address dhcpAcquire an IP address dynamically on an interface from the DHCP serv

Pagina 249 - Stacking Commands

Parametersinterface type slot/portDisplay DHCP client statistics on the specified interface.• For the management interface on the stack-unit, enter th

Pagina 250

Parameters0-5 Enter the stack member unit identifier of the stack member.all Enter the keyword all to set the primary, secondary, and default images f

Pagina 251

• To copy the running configuration, enter the keywords running-config.• To copy the startup configuration, enter the keywords startup-config.• To cop

Pagina 252

Password to login remote host? dillingExample (copy scp:)Dell#copy scp: flash:Address or name of remote host []: 10.11.199.134Port number of the serve

Pagina 253

dirDisplays the files in a file system. The default is the current directory.Syntaxdir [filename | directory name:]Parametersfilename | directory name

Pagina 254

Usage InformationYou must include the colon (:) when entering this command.CAUTION: This command deletes all files, including the startup configuratio

Pagina 255

renameRename a file in the local file system.Syntaxrename url urlParametersurl Enter the following keywords and a filename:• For a file on the interna

Pagina 256

When restoring units in stand-alone mode, the units remin in stand-alone mode after the restoration. After the restore is complete, the units power cy

Pagina 257 - System Time

• To copy the startup configuration, enter the keywords startup-config.• To copy a file on the external FLASH, enter usbflash:// then the filename.Com

Pagina 258

------------------------1 SuccessPower-cycling the unit(s).Dell#show boot systemDisplays information about boot images currently configured on the

Pagina 259

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.ExampleDell#show file flash://startup-config! Version 9-4(0-180)boot system stack-u

Pagina 260

Field Description• w = write accessPrefixes Displays the name of the storage location.Related Commandsformat flash – erases all the existing files and

Pagina 261

checksum runtime 1-0(0-1862) Control Processor passedCPLD IMAGE INFORMATION :--------------------------------------------------

Pagina 262

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.ExampleDell#show running-configCurrent Configuration ...! Version 9-4(0-180)!boot s

Pagina 263

Command FieldsLines Beginning WithDescriptionDell Force10 Network...Name of the operating systemDell Force10 Operating...OS version numberDell Force10

Pagina 264

ftp: After entering the keyword ftp:, you can either follow it with the location of the source file in this form: //userid:password@hostip/filepath or

Pagina 265 - Virtual Link Trunking (VLT)

userid:password@hostip/filepath, or press Enter to launch a prompt sequence.scp After entering the keyword scp you can either follow it with the locat

Pagina 266

FIP SnoopingIn a converged Ethernet network, a Switch can operate as an intermediate Ethernet bridge to snoop on Fibre Channel over Ethernet initializ

Pagina 267

fip-snooping enableEnable FIP snooping on all VLANs or on a specified VLAN.Syntaxfip-snooping enableTo disable the FIP snooping feature on all or a sp

Pagina 268

Example (copy scp:)Dell#copy scp: flash:Address or name of remote host []: 10.11.199.134Port number of the server [22]: 99Source file name []: test.cf

Pagina 269

Command ModesINTERFACECommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (PMUX) mode on

Pagina 270 - Debugging and Diagnostics

Defaults 10 minutesCommand ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.. This command is supported in Program

Pagina 271

iscsi enableGlobally enable iSCSI optimization.Syntaxiscsi enableTo disable iSCSI optimization, use the no iscsi enable command.Parametersenable Enter

Pagina 272

Defaults Dell Compellent disk arrays are not detected.Command ModesINTERFACECommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This c

Pagina 273

Basic Interface CommandsThe following commands are for Physical interfaces.clear countersClear the counters used in the show interfaces commands for a

Pagina 274

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (PMUX) mode only.Usage InformationIm

Pagina 275

Defaults• rx off• tx offCommand ModesINTERFACECommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Program

Pagina 276

flowcontrol rx off tx onno shutdown...Example (Values)This Example shows how the Dell Networking OS negotiates the flow control values between two Del

Pagina 277

• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.Defaults Not configured.Command ModesCONFIG

Pagina 278

The Management port is enabled by default (no shutdown). To assign an IP address to the Management port, use the ip address command.ExampleDell(conf)#

Pagina 279

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.dirDisplays the files in a file system. The default is the current directory.Syntax

Pagina 280

• The interface range prompt includes interface types with slot/port information for valid interfaces. The prompt allows for a maximum of 32 character

Pagina 281

interface vlan — configures a VLAN interface.interface vlanConfigure a VLAN. You can configure up to 4094 VLANs.Syntaxinterface vlan vlan-idTo delete

Pagina 282

Usage InformationIf you configure interface type as CR4 with auto-negotiation enabled, also configure CR4 with auto-negotiation. Many DAC cable link i

Pagina 283

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (PMUX) mode only.Usage InformationIf

Pagina 284

stack-unit port-group port mode ethernetConverts the interfaces 9 and 10 from Fibre Channel mode to Ethernet.Syntaxstack-unit unit number port-group 0

Pagina 285

• Forced-master• Force-slave• Master• Slave• Auto-neg Error — typically indicates that both ends of the node are configured with forced-master or forc

Pagina 286

• auto-negotiation enabled speed 100• auto-negotiation disabled speed 100• auto-negotiation disabled speed 100• auto-negotiation enabled* speed 1000 o

Pagina 287

The following describes the do show interfaces command shown in the following example. This example shows output with “Hybrid” as the newly added valu

Pagina 288 - NPIV Proxy Gateway

Port Channel CommandsA Link Aggregation Group (LAG) is a group of links that appear to a MAC client as if they were a single link according to IEEE 80

Pagina 289

the members have a link MTU of 2100 and an IP MTU 2000, the Port Channel’s MTU values cannot be higher than 2100 for link MTU or 2000 bytes for IP MTU

Pagina 290

Defaults flash memoryCommand ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationYou must include t

Pagina 291

Usage InformationPort Channel interfaces are logical interfaces and can be either in Layer 2 mode (by using the switchport command) or Layer 3 mode (b

Pagina 292

links before it can be declared as up. For example, if the required minimum is four, and only three are up, the LAG is considered down.Internet Group

Pagina 293

To return to the default value, use the no ip igmp querier-timeout command.Parametersseconds Enter the number of seconds the router must wait to becom

Pagina 294

Command ModesINTERFACECommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (PMUX) mode on

Pagina 295 - Data Center Bridging (DCB)

Defaults Disabled.Command Modes• CONFIGURATION• INTERFACE VLANCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supp

Pagina 296

Defaults 1000 millisecondsCommand ModesINTERFACE VLANCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in

Pagina 297

Defaults Not configured.Command ModesINTERFACE VLAN — (conf-if-vl-n)Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command i

Pagina 298

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationUsing the following example of a static route: ip route 33.33.33.0

Pagina 299

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThe following describes the show ip route all command in the follo

Pagina 300

Last Change ----------- ------- ----------- -----------*S 0.0.0.0/0 via 10.10.91.9, Te 1/2 1/0 3d2hDell#

Pagina 301

Command ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.ExampleDell#pwdflash:Dell#Related Commandscd – changes t

Pagina 302

Parametersmac-address Enter the 48-bit hexadecimal address in nn:nn:nn:nn:nn:nn format.output interfaceEnter the keyword output then one of the follow

Pagina 303

address/mac-address, interface/interface, or vlan vlan-id.static (OPTIONAL) Enter the keyword static to display only those MAC addresses specifically

Pagina 304 - I/O Aggregator

Column Heading DescriptionInterface Displays the interface type and slot/port information. The following abbreviations describe the interface types:•

Pagina 305

Line Beginning WithDescriptionDynamic Address...Lists the number of dynamically learned MAC addresses.Static Address... Lists the number of user-defin

Pagina 306

lacp port-priorityTo influence which ports will be put in Standby mode when there is a hardware limitation that prevents all compatible ports from agg

Pagina 307

Usage InformationLACP ModesMode Functionactive An interface is in an active negotiating state in this mode. LACP runs on any link configured in the ac

Pagina 308

The starting point for using LLDP is invoking LLDP with the protocol lldp command in either CONFIGURATION or INTERFACE mode.The information LLDP distr

Pagina 309

Command ModesCONFIGURATION (conf-lldp)Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mu

Pagina 310

debug lldp interfaceTo display timer events, neighbor additions or deletions, and other information about incoming and outgoing packets, enable LLDP d

Pagina 311

disableEnable or disable LLDP.SyntaxdisableTo enable LLDP, use the no disable command.Defaults Enabled, that is no disable.Command ModesCONFIGURATION

Pagina 312

nvram Enter the keyword nvram to reset the NvRAM only.Command ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Us

Pagina 313

Defaults 4 x helloCommand ModesCONFIGURATION (conf-lldp) and INTERFACE (conf-if-interface-lldp)Command HistoryVersion 9.4(0.0) Supported on the FN I/O

Pagina 314

The dcb-map command is supported only on physical Ethernet interfaces.To remove a DCB map from an interface, enter the no dcb-map map-name command in

Pagina 315

fabric-id vlanIn an FCoE map, configure the association between the dedicated VLAN used to carry FCoE traffic between servers and a SAN, and the fabri

Pagina 316

Parametersfc-map-value Enter the unique MAC address prefix used by a SAN fabric.The range of FC-MAP values is from 0EFC00 to 0EFCFF.Defaults NoneComma

Pagina 317

• Fc-map: 0x0efc00• Fcf-priority: 128• Fka-adv-period: 8000mSec• Keepalive: enable• Vlan priority: 3Command ModesCONFIGURATIONINTERFACECommand History

Pagina 318

Parameterspriority Enter the priority assigned to the FN 2210S Aggregator NPIV proxy gateway, which appears to a downstream server CNA as an FCF. The

Pagina 319

Related Commandsfcoe-map — creates an FCoE map which contains the parameters used in the communication between servers and a SAN fabric.show fcoe-map—

Pagina 320

Command HistoryVersion 9.6(0.0) Supported on the FN2210S Aggregator.Version 9.3(0.0) Introduced on the M I/O Aggregator and MXL 10/40GbE Switch with t

Pagina 321

Field DescriptionFabric ID The ID number of the SAN fabric to which FC traffic is forwarded.VLAN ID The dedicated FCoE VLAN used to transport FCoE sto

Pagina 322

Oper-State DOWN Members Related Commandsfcoe-map — creates an FCoE map which contains the parameters used in the communi

Pagina 323

2 Success3 Not present4 Not present5 Not presentPower-cycling the unit(s).Dell#Example (NvRAM, single unit)Dell#restore factory-defaults s

Pagina 324

The following table describes the show npiv devices brief output shown in the example below.Field DescriptionENode-Intf M I/O Aggregator and MXL 10/40

Pagina 325

Field DescriptionEnode MAC MAC address of a server CNA port.Enode Intf Port number of a server-facing Ethernet port operating in ENode mode.FCF MAC Fi

Pagina 326

Fabric Intf : Fc 0/0FCoE Vlan : 1003Fabric Map : fid_1003ENode WWPN : 10:00:00:00:c9:d9:9c:cbENode WWNN : 10:00:00:00:c9

Pagina 327

Te 0/10 Up 10000 Mbit Full --Te 0/11 Up 10000 Mbit Full --Te 0/12 Up 10000 Mbit Full --Del

Pagina 328

PG:1 TSA:ETS BW:50 PFC:ONPriorities:3Related Commandsdcb-map — creates a DCB map to configure PFC and ETS parameters and applies the PFC and ETS set

Pagina 329

Usage InformationThe dot1p-priority command changes the priority of incoming traffic on the interface. The system places traffic marked with a priorit

Pagina 330

assigned to the port channel are automatically configured; you cannot assign the service-class dynamic command to individual interfaces in a port chan

Pagina 331

service-class bandwidth-percentageSpecify a minimum bandwidth for queues.Syntaxservice-class bandwidth-percentage queue0 number queue1 number queue2 n

Pagina 332

Defaults noneCommand ModesCONFIGURATION (conf-qos-policy-out)Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is suppo

Pagina 333

Parametersqos-policy-nameEnter the name of the policy map in character format (32 characters maximum).Defaults noneCommand ModesCONFIGURATION (policy-

Pagina 334

restore factory-defaults... 37show

Pagina 335

Stack-unit 4 is not present.Stack-unit 5 is not present.show fileDisplays contents of a text file in the local filesystem.Syntaxshow file urlParameter

Pagina 336

Related Commandsservice-queue — assigns a class map and QoS policy to different queues.policy-aggregate — allows an aggregate method of configuring pe

Pagina 337

Defaults Granularity for rate is Mbps unless you use the kbps option.Command ModesQOS-POLICY-OUTCommand HistoryVersion 9.4(0.0) Supported on the FN I/

Pagina 338

Parametersqueue-id Enter the value used to identify a queue. The range is from 0 to 3 (four queues per interface; four queues are reserved for control

Pagina 339

Qos-policy-output qmap_wgRate-shape 100 50Wred yellow wyWred green wgDell#trustSpecify dynamic classification (DSCP) or dot1p to trust.Syntaxtrust {di

Pagina 340

DSCP/CP hex Range (XXX)DSCP DefinitionTraditional IP PrecedenceMXL Switch Internal Queue IDDSCP/CP Decimal000XXX BE (Best Effort)Best Effort 0 0–15Sec

Pagina 341

commands levelEnter the keyword command then a privilege level for accounting of commands executed at that privilege level.name | default Enter one of

Pagina 342

Defaults Accounting records are recorded for all users.Command ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Us

Pagina 343

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThis command steps through all active sessions and then displays t

Pagina 344 - Basic Interface Commands

Defaults Use the enable password.Command ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationBy defa

Pagina 345

• radius: use the RADIUS servers configured with the radius-server host command.• tacacs+: use the TACACS+ servers configured with the tacacs-server h

Pagina 346

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.ExampleDell#show file-systemsSize(b) Free(b) Feature Type Flags Pref

Pagina 347

banner execConfigure a message that is displayed when your enter EXEC mode.Syntaxbanner exec c line cTo delete a banner, use the no banner exec comman

Pagina 348

line — enables and configures the console and virtual terminal lines to the system.banner loginSet a banner to display when logging on to the system.S

Pagina 349

This is the bannerDell>Related Commandsexec-banner— enables the display of a text string when you enter EXEC mode.debug radiusView RADIUS transacti

Pagina 350

Related Commandsbanner exec— configures a banner to display when entering EXEC mode.line — enables and configures console and virtual terminal lines t

Pagina 351

Defaults Not configured.Command ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.login authenticationTo designate

Pagina 352

Parametersseconds Enter a number of seconds during which non-responsive RADIUS servers are skipped. The range is from 0 to 2147483647 seconds. The def

Pagina 353

Configure this parameter last because leading spaces are ignored.Defaults Not configured.Command ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Sup

Pagina 354

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Related Commandsradius-server host — configures a RADIUS host.radius-server timeout

Pagina 355

Command ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThe key configured on the switch must ma

Pagina 356

• show system stack-ports• show system stack-unit stack-group• stack-unit iom-modepower-cycle stack-unitTo hard reset any stack unit including master

Pagina 357

• For a file on a TFTP server, enter tftp://hostip/filepath.• For a file on the external Flash, enter usbflash://filepath then the filename.Defaults n

Pagina 358

ExampleDell#show system briefStack MAC : 00:1e:c9:f1:00:9b-- Stack Info --Unit UnitType Status ReqTyp CurTyp Version

Pagina 359

Command Modes• EXEC• EXEC PrivilegeCommand HistoryVersion 9.6.(0.0)Supported on the FN I/O Aggregator.Usage InformationThis command is supported on th

Pagina 360

Related Commandspower-cycle stack-unit—resets the designated stack member.show diag— displays the data plane or management plane input and output stat

Pagina 361

show system stack-unit iom-modeDisplays the current iom-mode (stack/standalone) and the mode configured after next reboot.Syntaxshow system stack-unit

Pagina 362

| Pipe through a command<cr>Dell#show system stack-unit 0 stack-group configuredConfigured stack groups in stack-unit 0Dell#show

Pagina 363 - IGMP Snooping Commands

Parameters0-5 The first instance of this value is the stack member unit identifier, from 0 to 5, of the switch that you want add to the stack. The ran

Pagina 364

TACACS+ CommandsDell Networking OS supports TACACS+ as an alternate method for login authentication.tacacs-server hostSpecify a TACACS+ host.Syntaxtac

Pagina 365

tacacs-server keyConfigure a key for communication between a TACACS+ server and a client.Syntaxtacacs-server key [encryption-type] keyTo delete a key,

Pagina 366

Command ModesLINECommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThe software measures the period of inactivity de

Pagina 367

• Passwords can have a regular expression as the password. To create a password with a regular expression in it, use CNTL + v prior to entering regula

Pagina 368

bootfor the current boot configurationftp for the current FTP configurationigmpfor the current IGMP configurationinterfacefor the current interface co

Pagina 369

Command ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationCAUTION: Encrypting passwords with this

Pagina 370

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThis command displays the contents of the flash://ADMIN_DIRssh/kno

Pagina 371

Command ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThe following describes the show user c

Pagina 372

-v {1 | 2} (OPTIONAL) Enter the keyword -v then the SSH version 1 or 2. The default is the version from the protocol negotiation.Defaults As shown in

Pagina 373

secret Enter the keyword secret then the encryption type.Defaults The default encryption type for the password option is 0. The default encryption typ

Pagina 374

• SNMP v3 informs are not currently supported with IPv6 addresses.• If you are using access control lists (ACLs) in an SNMP v3 configuration, group AC

Pagina 375

ipv6-address Enter the keyword host then the IPv6 address of the host in the x:x:x:x::x format.NOTE: The :: notation specifies successive hexadecimal

Pagina 376

• envmon — Enable SNMP environmental monitor traps.• eoam — Enable EOAM state change traps• ets — Enable ets traps• fips — Enable FIP Snooping state c

Pagina 377

NOTE: For v1 / v2c trap configuration, if the community-string is not defined using the snmp-server community command prior to using this command, the

Pagina 378

NOTE: The :: notation specifies successive hexadecimal fields of zeros.hostname Enter the name of a host already configured and recognized by the swit

Pagina 379

show versionDisplays the current Dell Networking OS version information on the system.Syntaxshow versionCommand ModesEXEC PrivilegeCommand HistoryVers

Pagina 380

Related Commandsclear logging — clears the logging buffer.show logging — displays the logging setting and system messages in the internal buffer.loggi

Pagina 381

Command ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (PMUX) mod

Pagina 382

Parametersnumber (OPTIONAL) Enter the number of messages displayed in the output. The range is from 1 to 65535.history (OPTIONAL) Enter the keyword hi

Pagina 383

Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Session closed by neighbor 1.1.10.2 (Hold time expired)Oct 8 09:25:38: %RPM1:RP1 %BGP-5-ADJCHANGE: Neighbo

Pagina 384

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (PMUX) mode only.Related Commandslog

Pagina 385

• For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.Defaults noneCommand Modes• EXEC• EXEC Priv

Pagina 386

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThis command is available only in PMUX mode.storm-control unknown-

Pagina 387

Where port-range and port-channel-range specify a range of ports separated by a dash (-) and/or individual ports/port channels in any order; for examp

Pagina 388

descriptionEnter a text description of an uplink-state group.Syntaxdescription textParameterstext Text description of the uplink-state group. The maxi

Pagina 389

Parametersinterface Enter one of the following interface types:• 10 Gigabit Ethernet: tengigabitethernet {slot/port |slot/port-range}• Port channel: p

Pagina 390

Lines Beginning WithDescriptionControl Processor:...Control processor information and amount of memory on processor256M bytes... Amount of boot flash

Pagina 391

Command ModesUPLINK-STATE-GROUPCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (PMUX

Pagina 392

show running-config uplink-state-groupDisplay the current configuration of one or more uplink-state groups.Syntaxshow running-config uplink-state-grou

Pagina 393

Command Modes• EXEC• EXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator. This command is supported in Programmable-Mux (

Pagina 394

An uplink-state group is considered to be operationally down if no upstream interfaces in the group are in the Link-Up state. No uplink-state tracking

Pagina 395

You can assign an interface to only one uplink-state group. Configure each interface assigned to an uplink-state group as either an upstream or downst

Pagina 396

back-up destinationConfigure the IPv4 or IPv6 address of the management interface on the remote VLT peer to be used as the endpoint of the VLT backup

Pagina 397 - Policy-Based QoS Commands

ARP-sync Pkts Sent:0ARP-sync Pkts Rcvd:0ARP Reg Request sent:19ARP Reg Request rcvd:10lacp ungroup member-independentPrevent possible loop during the

Pagina 398

peer-link port-channelConfigure the specified port channel as the chassis interconnect trunk between VLT peers in the domain.Syntaxpeer-link port-chan

Pagina 399

Vlan IPV4 Multicast Status-------------------------- Vlan-ID Local Status Peer Status -------- ------------ ----------- 4094

Pagina 400

Usage InformationWhen you create a VLT domain on a switch, Dell Networking OS automatically assigns a unique unit ID (0 or 1) to each peer switch. The

Pagina 401

A: Enter this keyword to upgrade the bootflash partition A.B: Enter this keyword to upgrade the bootflash partition B.Defaults noneCommand ModesEXEC P

Pagina 403

AInternet Control Message Protocol (ICMP) Message TypesThis chapter lists and describes the possible ICMP message type resulting from a ping. The firs

Pagina 404

Symbol Type Code Description Query Error0 redirect for network . 1 redirect for host . 2 redirect for type-of-service and network. 3 redirect for type

Pagina 405

usbflash After entering the keyword usbflash you can either follow it with the location of the source file in this form://filepath, or press Enter to

Pagina 406

5Control and MonitoringThis chapter describes control and monitoring for the I/O Aggregator.asset-tagAssign and store a unique asset-tag to the stack

Pagina 407

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThis command clears alarms that are no longer active. If an alarm

Pagina 408

show processes memory...69show revisi

Pagina 409

Defaults DisabledCommand ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThis command enables (

Pagina 410

disableReturn to EXEC mode.Syntaxdisable [level]Parameterslevel (OPTIONAL) Enter a number for a privilege level of the Dell Networking OS. The range i

Pagina 411

endReturn to EXEC Privilege mode from other command modes (for example, CONFIGURATION mode).SyntaxendCommand Modes• CONFIGURATION• LINE• INTERFACE• MO

Pagina 412

Command ModesCONFIGURATIONCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Examplemorpheus% ftp 10.31.1.111Connected to 10.31.1.111.

Pagina 413

Related Commandsftp-server enable — enables FTP server functions on the I/O Aggregator.ftp-server username — sets a username and password for incoming

Pagina 414

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationThe hostname is used in the prompt.ip telnet server enableEnable t

Pagina 415

lineEnable and configure console and virtual terminal lines to the system. This command accesses LINE mode, where you can set the access conditions fo

Pagina 416

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationWhen you enter the ping command without specifying an IP address (

Pagina 417

log (OPTIONAL) Enter the keyword log to add timestamps to log messages with severity from 0 to 6.datetime (OPTIONAL) Enter the keyword datetime to hav

Pagina 418

----------------------------------------No major alarmsDell#Dell# show alarms threshold -- Temperature Limits (deg C) ------------------------------

Pagina 419

clear dcbx counters... 95clea

Pagina 420

default fromconsole[4/20 10:27:24]: CMD-(CLI):[line console 0]by default from console[4/20 10:27:24]: CMD-(CLI):[exec-timeout 0]by default from consol

Pagina 421

entering CONFIGURATION mode. Rollback indicates that Dell Networking OS is in a rollback process. The line number shown in the output can be used to s

Pagina 422

Related Commandsdebug cpu-traffic-stats — enables CPU traffic statistics for debugging.show debuggingView a list of all enabled debugging processes.Sy

Pagina 423

Defaults SummaryCommand ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.show environmentView system component st

Pagina 424

* Management UnitExample (thermal-sensor)Dell#show environment thermal-sensor -- Thermal Sensor Readings (deg C) --Unit Sensor0 Sensor1 Sensor2-

Pagina 425

iSCSI LLDP SNMP Dell#Example (media)Dell#show inventory media ?<0-5> Slot number |

Pagina 426

=========================== Total(b) Used(b) Free(b) Lowest(b) Largest(b) 2147483648 9841262 2137642386 213447

Pagina 427

0x00000000 2120 212 10000 3.77% 3.77% 3.77% 0system0x00000112 2472940 247294 10000 0.79% 0.61% 0.65% 0sysdlp0x000000e4 495560

Pagina 428

show processes ipc flow-controlDisplay the single window protocol queue (SWPQ) statistics.Syntaxshow processes ipc flow-control [cp] Parameterscp (OPT

Pagina 429

• In the example, a retry (Retries) value of zero indicates that the SWP mechanism reached the maximum number of retransmissions without an acknowledg

Pagina 430

show ip igmp interface...132show ip

Pagina 431

summary Enter the keyword summary for a brief summary of memory availability and usage on all stack members.Command Modes• EXEC• EXEC PrivilegeCommand

Pagina 432

CurrentHoldingf10appioserv 225280 0 0 192512fcoecntrl 270336 0 0 92

Pagina 433

160 vrrp 7712768 335872 880 0 880880318 frrp 7192576 180224 71086 66256 213944830218

Pagina 434 - SNMP Commands

TenGigabitEthernet 0/5 YES up upTenGigabitEthernet 0/6 NO up downTenGigabitEthernet 0/7 YES up upTenGigabitEthernet 0/8

Pagina 435

stack unit unit–id(OPTIONAL) Enter the keywordsstack unit then the stack member ID for information on the stack member. The range is from 0 to 5.Comma

Pagina 436

Piece Part ID : TW-07NVPV-00000-000-0014PPID Revision : X01Service Tag : N/AExpr Svc Code : N/AC

Pagina 437

save Enter the keyword save to save the command output.flash: Save to local flash drive (flash://filename (max 20 chars))Command Modes• EXEC Privilege

Pagina 438 - Syslog Commands

page Page through output| Pipe through a command<cr>Dell#show tech-support stack-unit 1 | ?except S how only text that

Pagina 439

----------------------------------- show running-config ------------------------Current Configuration ...! Version 1-0(0-1864)! Last configuration ch

Pagina 440

---------------- show uplink brief ---------------------Interface OK Status Protocol DescriptionTenGigabitEthernet 0/9 NO u

Pagina 441

ip route...

Pagina 442

TenGigabitEthernet 0/2 is up, line protocol is upHardware is DellEth, address is 00:1e:c9:de:03:79 Current address is 00:1e:c9:de:03:79Server Port

Pagina 443

ssh-peer-stack-unitOpen an SSH connection to the peer stack-unit.Syntaxssh-peer-stack-unit [-| username]Parameters-| username (OPTIONAL) Enter the key

Pagina 444

Defaults Not configured.Command Modes• EXEC• EXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.Usage InformationTelnet

Pagina 445

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.terminal monitorConfigure the Dell Networking OS to display messages on the monitor

Pagina 446

trace routeView the packet path to a specific device.Syntaxtraceroute {host | ip-address}ParametershostEnter the name of device.ip-address Enter the I

Pagina 447

undebug allDisable all debug operations on the system.Syntaxundebug allDefaults noneCommand Modes• EXEC PrivilegeCommand HistoryVersion 9.4(0.0) Suppo

Pagina 448

6u-BootAll commands in this chapter are in u-Boot mode. These commands are supported on the Dell Networking Aggregator only.To access this mode, hit E

Pagina 449

ExampleBOOT_USER# boot show net config retriesNumber of Network Boot Config Retries is : 0BOOT_USER #boot write net config retriesSet the number of re

Pagina 450

enableChange the access privilege level.Syntaxenable [user| admin]Command Modes• uBootCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregat

Pagina 451

ignore enable passwordIgnore the enabled password.Syntaxignore enable-passwordCommand Modes• uBootCommand HistoryVersion 9.4(0.0) Supported on the FN

Pagina 452

19 Port Monitoring...202description...

Pagina 453

Command HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.no interface management ethernet ip addressClear the management port IP address and

Pagina 454

BOOT_USER #show boot selectionDisplays the ROM bootstrap bootflash partition.Syntaxshow boot selectionCommand Modes• uBootCommand HistoryVersion 9.4(0

Pagina 455

Dell Force10 Networks System Boot Official IOM_XLOAD_LP_IMG_BOOT_SELECTOR, BSP Release 4.0.0.0bt1 Created Tue May 1 10:56:34 2012 by build on l

Pagina 456

Command Modes• uBootCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.ExampleBOOT_USER # show default-gatewayGateway IP address: 15.0

Pagina 457

syntax helpShow the syntax information.SyntaxhelpCommand Modes• uBootCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.94

Pagina 458

7Data Center Bridging (DCB)Data center bridging (DCB) refers to a set of IEEE Ethernet enhancements that provide data centers with a single, robust, c

Pagina 459

Command ModesEXEC PrivilegeCommand HistoryVersion 9.4(0.0) Supported on the FN I/O aggregator.clear ets countersClear ETS TLV counters.Syntaxclear ets

Pagina 460

Usage informationIf you do not use the statistics parameter, both hardware and DCBx counters clear.dcb enable auto-detect on-next-reloadEnables or dis

Pagina 461 - Message Types

Proceed with reload [confirm yes/no]: ysyncing disks... doneunmounting file systems...unmounting /f10/flash (/dev/ld0e)...unmounting /usr (mfs:35)...u

Pagina 462

unmounting /usr (mfs:35)...unmounting /lib (mfs:24)...unmounting /f10 (mfs:21)...unmounting /tmp (mfs:15)...unmounting /kern (kernfs)...unmounting / (