80 Troubleshooting
Table 6-8 lists the critical and warning events, severity levels of the events, and audible codes.
NOTE: If the PERC 5/E alarm was already beeping due to a previous failure and a new virtual disk is created on the
same controller, then the previous alarm will be silenced. This is expected behavior.
Table 6-8. Audible Alarm Descriptions
Description Severity Audible Code
Controller alarm enabled Normal N/A
Virtual disk failed Critical 3 seconds on, 1 second off
Virtual disk degraded Warning 1 second on, 1 second off
Global hot spare failed Warning 1 second on, 1 second off
Dedicated hot spare failed Warning 1 second on, 1 second off
Physical disk failed Critical 1 second on, 1 second off
Rebuild completed on physical disk Normal 1 second on, 3 seconds off
Rebuild failed on physical disk Warning 1 second on, 1 second off
Physical disk offline Critical 1 second on, 1 second off
Dell_PERC5_UG.book Page 80 Tuesday, February 13, 2007 6:02 PM