Pagina 1 - Deployment Guide

Dell PowerVault MD3260i Series Storage ArraysDeployment Guide

Pagina 2 - Notes, Cautions, and Warnings

Redundant And Non-Redundant ConfigurationsNon-redundant configurations are configurations that provide only a single data path from a host to the stor

Pagina 3 - Contents

Figure 1. Eight Hosts With a Single Data PathIn the following figure, up to four servers are directly attached to the RAID controller modules. If the

Pagina 4

Figure 2. Four Hosts Connected to Two ControllersIn the following figure, up to four cluster nodes are directly attached to two RAID controller module

Pagina 5

Figure 3. Four Cluster Nodes Connected to Two ControllersNetwork-Attached ConfigurationsYou can also cable the host servers to the RAID controller mod

Pagina 6

the PowerVault MD3260i Series storage array can support up to 64 hosts simultaneously. This configuration supports single-path data configurations.The

Pagina 7 - Introduction

Figure 4. 64 Servers Connected to Two Controllers15

Pagina 8

Cabling PowerVault MD3060e Expansion EnclosuresYou can expand the capacity of your PowerVault MD3260i Series storage array by adding PowerVault MD3060

Pagina 9 - Hardware Installation

3Installing MD Storage ManagerThe PowerVault MD Series resource media contains software and drivers for both Linux and Microsoft Windows operating sys

Pagina 10

Modular Disk Configuration UtilityThe PowerVault MD Configuration Utility (MDCU) is an optional utility that provides a consolidated approach for conf

Pagina 11

NOTE: The MD Storage Manager installer automatically installs the required drivers, firmware, and operating system patches/hotfixes to operate your st

Pagina 12

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Pagina 14

4Post Installation TasksBefore using the storage array for the first time, complete a number of initial configuration tasks in the order shown. These

Pagina 15

iSCSI Configuration WorksheetThe IPv4 Settings — Worksheet and IPv6 Settings — Worksheet helps you plan your configuration. Recording host server and

Pagina 16

• Host configurationStorage Array ConfigurationBefore a host iSCSI initiator and an iSCSI-based storage array can communicate, they must be configured

Pagina 17 - Installing MD Storage Manager

• For redundancy in a dual controller (duplex) configuration, ensure each host network interface is configured to connect to both storage array contro

Pagina 18

5Guidelines For Configuring Your Network For iSCSIThis section provides general guidelines for setting up your network environment and IP addresses fo

Pagina 19 - Silent Installation

3. Restart network services using the following command:/etc/init.d/network restartUsing A DNS ServerIf you are using static IP addressing:1. In the C

Pagina 20

NETWORKING=yes HOSTNAME=mymachine.mycompany.com2. Edit the configuration file for the connection you want to configure, either /etc/sysconfig/network-

Pagina 22

6Uninstalling MD Storage ManagerUninstalling MD Storage Manager From WindowsUninstall MD Storage Manager From Microsoft Windows Operating Systems Othe

Pagina 24

Uninstalling MD Storage Manager From LinuxBy default, PowerVault MD Storage Manager is installed in the /opt/dell/mdstoragemanager directory. If anoth

Pagina 25 - Microsoft Windows Host Setup

7Appendix — Manual Configuration Of iSCSIThe following sections contain step-by-step instructions for configuring iSCSI on your storage array. However

Pagina 26 - Linux Host Setup

Automatic Storage Array Discovery1. Launch MD Storage Manager.If this is the first storage array to be set up, the Add New Storage Array window is dis

Pagina 27 - Using A Static IP Address

Task PurposeConfigure a storage array To create virtual disks and map them to hosts.Step 2: Configure The iSCSI Ports On The Storage ArrayBy default,

Pagina 28

For Windows Server 2003 Or Windows Server 2008 GUI Version1. Click Start→ Programs→ Microsoft iSCSI Initiator or click Start→ All Programs→ Administra

Pagina 29 - Microsoft Windows Server 2008

a) Edit or verify that the node.startup = manual line is disabled.b) Edit or verify that the node.startup = automatic line is enabled.This enables aut

Pagina 30

Target CHAPIn target CHAP, the storage array authenticates all requests for access issued by the iSCSI initiator(s) on the host server using a CHAP se

Pagina 31

CHAP Setting DescriptionNone This is the default selection. If None is the only selection, the storage array allows an iSCSI initiator to log on witho

Pagina 32 - Setting Up The Array

3. If you are using mutual CHAP authentication, click the General tab and select Secret. At Enter a secure secret, enter the mutual CHAP secret you en

Pagina 33

For Red Hat Enterprise Linux 5 Or 6, SUSE Linux Enterprise Server 10 Or 111. To enable CHAP (optional), the following line needs to be enabled in your

Pagina 34

Using A WINS Server...

Pagina 35 - Step 4: Configure Host Access

9. Go to Connected Targets.10. Verify that the targets are connected and the status is true.Step 7: Connect To The Target Storage Array From The Host

Pagina 36 - (Optional)

3. Log on to the target:iscsicli PersistentLoginTarget Target_NameReport_To_PNP Target_Portal_AddressTCP_Port_Number_Of_Target_Portal * * *Login_Flags

Pagina 37

To review optimal network setup and configuration settings, see Guidelines For Configuring Your Guidelines For Configuring Your Network For iSCSI.Step

Pagina 38

8Appendix — Using Internet Storage Naming ServiceInternet Storage Naming Service (iSNS) server, supported only on Microsoft Windows iSCSI environments

Pagina 40

9Appendix — Load BalancingWindows Load Balance PolicyMulti-path drivers select the I/O path to a virtual disk through a specific RAID controller modul

Pagina 41 - For Linux Server

The Computer Management window is displayed.2. Click Device Manager to show the list of devices attached to the host.3. Right-click the multi-path dis

Pagina 42

Figure 5. Initiator ConfigurationTwo sessions with one TCP connection are configured from the host to each controller (one session per port), for a to

Pagina 44

10Appendix — Stopping And Starting iSCSI Services In LinuxTo manually stop the iSCSI services in Linux, certain steps must be followed to maintain par

Pagina 45 - Appendix — Load Balancing

Step 8: (Optional) Set Up In-Band Management... 428 A

Pagina 47

11IPv4 Settings — Worksheet NOTE: If you need additional space for more than one host server, use an additional sheet.Static IP address (host server)

Pagina 48

Static IP address (host server) Subnet A(must be different for each NIC)Default gatewayiSCSI port 0, In 2 ___ . ___ . ___ . ___ ___ . ___ . ___ . ___

Pagina 49 - Services In Linux

12IPv6 Settings — Worksheet NOTE: If you need additional space for more than one host server, use an additional sheet.Host iSCSI port 1 Host iSCSI por

Pagina 50

Router IP address ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____iSCSI controller 0, In 1IP address FE80 : 0000 : 0000 : 0000 : ____ : ____ : __

Pagina 51 - IPv4 Settings — Worksheet

iSCSI controller 1, In 3IP address FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____Routable IP address 1 ____ : ____ : ____ : ____ : ____ : ____

Pagina 53 - IPv6 Settings — Worksheet

1IntroductionThis guide provides information about deploying Dell PowerVault MD3260i storage arrays. The deployment process includes:• Hardware instal

Pagina 54

One or more host servers attached to the storage array can access the data on the storage array. You can also establish multiple physical paths betwee

Pagina 55

2Hardware InstallationBefore using this guide, ensure that you review the instructions in the:•Getting Started Guide — The Getting Started Guide that