Traps 645
Table 25-6. Amperage Probe Traps
Trap ID Description Severity Cause
Amperage Probe Normal
1202 Current sensor returned to
a normal value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was:
<State>
If sensor type is not
discrete: Current sensor
value (in Amps): <Reading>
If sensor type is
discrete: Discrete current
state: <State>
Information A current sensor on the
power supply for the
specified system
returned to a valid range
after crossing a failure
threshold. The sensor
location, chassis
location, previous state,
and current sensor value
are provided.
Amperage Probe Warning
1203 Current sensor detected a
warning value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was:
<State>
If sensor type is not
discrete: Current sensor
value (in Amps): <Reading>
If sensor type is
discrete: Discrete current
state: <State>
Warning A current sensor on the
power supply for the
specified system
exceeded its warning
threshold. The sensor
location, chassis
location, previous state,
and current sensor value
are provided.