Dell OpenManage Server Administrator Version 6.2 Guida Utente Pagina 381

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 760
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 380
Memory Group 381
Table 15-6. Physical Memory Configuration Redundant Settings
Variable Name:
DellPhysicalMemoryConfigRedundantSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no redundant memory settings enabled.
unknown(1) Redundant settings are unknown.
The following redundant settings are mutually exclusive:
spareEnabled(2) Spare redundant memory feature is enabled.
mirrorEnabled(4) Mirror redundant memory feature is enabled.
raidEnabled(8) RAID redundant memory feature is enabled.
Table 15-7. Physical Memory Logging Capabilities
Variable Name:
DellPhysicalMemoryLoggingCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
If set to 0 (zero) There are no logging capabilities.
unknown Capabilities(1) Logging capabilities are unknown.
The logging capabilities are:
enableCapable(2) Logging enable/disable using Simple Network
Management Protocol (SNMP) is supported.
Vedere la pagina 380
1 2 ... 376 377 378 379 380 381 382 383 384 385 386 ... 759 760

Commenti su questo manuale

Nessun commento