Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Manuale Utente Pagina 222

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 316
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 221
222 omconfig storage Commands
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
To erase the data on physical disk 3 on connector 0 of controller 1:
For SCSI, SATA, and ATA controllers:
omconfig storage pdisk action=instantsecureerase
controller=1 pdisk=0:3
For SAS controllers:
omconfig storage pdisk action=remove controller=1
pdisk=0:2:3
NOTE: On a SAS controller, the physical disk resides in enclosure 2.
omconfig Initialize Physical Disk
Use the following omconfig command syntax to initialize a physical disk.
Complete Syntax
omconfig storage pdisk action=initialize
controller=id pdisk=<PDISKID>
where id is the controller ID. The <PDISKID> variable specifies the
physical disk.
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage vdisk controller=ID to display
the IDs for the physical disks attached to the controller.
Example Syntax
To initialize physical disk 4 on controller 1, type:
omconfig storage pdisk action=initialize
controller=1 pdisk=4
Vedere la pagina 221
1 2 ... 217 218 219 220 221 222 223 224 225 226 227 ... 315 316

Commenti su questo manuale

Nessun commento