Dell 3348 - PowerConnect Switch - Stackable Guida Utente Pagina 322

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 378
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 321
322 Viewing Statistics
www.dell.com | support.dell.com
• Click Statistics/RMON > RMON> Alarms in the Tree View. The RMON Alarm
page opens.
RMON Alarm Page
The RMON Alarm page contains the following fields:
• Alarm Entry—Indicates a specific alarm.
• Counter Name—Indicates the selected RMON counter.
• Counter Value—Indicates the value of the RMON counter.
• Sample Type—Specifies the sampling method for the selected variable and compares
the value against the thresholds. The possible field values are:
– Delta—Subtracts the last sampled value from the current value. The difference in
the values is compared to the threshold.
– Absolute—Compares the values directly with the thresholds at the end of the
sampling interval.
• Rising Threshold—The rising counter value that triggers the rising threshold alarm.
Vedere la pagina 321
1 2 ... 317 318 319 320 321 322 323 324 325 326 327 ... 377 378

Commenti su questo manuale

Nessun commento