Vedere la pagina 164
Power Group 167
Amperage Probe Status
Amperage Probe Reading
Name amperageProbeStatus
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.5
Description Defines the status of the amperage probe.
Syntax DellSigned32BitRange
Access Read-only
Name amperageProbeReading
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.6
Description Defines the reading for an amperage probe of type other than
amperageProbeTypeIsDiscrete.
When the value for amperageProbeType is
amperageProbeTypeIsPowerSupplyAmps or
amperageProbeTypeIsSystemAmps, the value returned for this
attribute is the power usage that the probe is reading in tenths
of Amperes.
When the value for amperageProbeType is
amperageProbeTypeIsPowerSupplyWatts or
amperageProbeTypeIsSystemWatts, the value returned for this
attribute is the power usage that the probe is reading in Watts.
When the value for amperageProbeType is other than
amperageProbeTypeIsDiscrete,
amperageProbeTypeIsPowerSupplyAmps,
amperageProbeTypeIsPowerSupplyWatts,
amperageProbeTypeIsSystemAmps, or
amperageProbeTypeIsSystemWatts, the value returned for this
attribute is the amperage that the probe is reading in Milliamps.
When the value for amperageProbeType is
amperageProbeTypeIsDiscrete, a value is not returned for this
attribute.
Syntax DellSigned32BitRange
Access Read-only