644 Storage Management Group
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
DELL CONFIDENTIAL – PRELIMINARY 3/6/13 - FOR PROOF ONLY
Power Supply State
Power Supply Severity
Power Supply 1 Part Number
Name powerSupplyState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.4
Description Identifies the current state of the power supply. Possible states:
0: Unknown
1: Ready
2: Failed
5: Not Installed
6: Degraded
11: Removed
Syntax Integer
Access Read-only
Name powerSupplySeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.5
Description This entry is obsolete for Storage Management. It is replaced with
RollUpStatus and ComponentStatus for each device.
Syntax Integer
Access Read-only
Name powerSupply1PartNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.6
Description Identifies the part number of the power supply of the enclosure.
Syntax DisplayString
Access Read-only