Table 1-38. Sensory Device Commands (NetFn: 04H)
Command NetFn CMD O/M Supported
Get Device SDR Info S/E 20h O No
Get Device SDR S/E 21h O No
Reserve Device SDR Repository S/E 22h O No
Get Sensor Reading Factors S/E 23h O Yes
Set Sensor Hysteresis S/E 24h O Yes
Get Sensor Hysteresis S/E 25h O Yes
Set Sensor Threshold S/E 26h O Yes
Get Sensor Threshold S/E 27h O Yes
Set Sensor Event Enable S/E 28h O Yes
Get Sensor Event Enable S/E 29h O Yes
Set Sensor Reading and Event Status S/E 30h O Yes
Re-arm Sensor Events S/E 2Ah O Yes
Get Sensor Event Status S/E 2Bh O Yes
Get Sensor Reading S/E 2Dh M Yes
Set Sensor Type S/E 2Eh O No
Get Sensor Type S/E 2Fh O No
Table 1-39. Event Commands (NetFn: 04H)
Command NetFn CMD O/M Supported
Set Event Receiver S/E 00h M Yes
Get Event Receiver S/E 01h M Yes
Platform Event S/E 02h M Yes