Table 1-50. Threshold Settings and Converting Formulas
(continued)
Sensor
Number
Sensor Name The Converting Formula
Upper non-
recoverable
Upper
critical
Upper
non-
critical
Lower non-
recoverable
Lower
critical
Lower
non-
critical
Temperature
40h MEZZ1 Temp Actual_Reading (degrees C) = Raw_Data - 128
C6 BC B0 8F 97 A0
41h CPU1 Temp Actual_Reading (degrees C) = Raw_Data
5A 50 46 20 25 29
42h CPU2 Temp Actual_Reading (degrees C) = Raw_Data
5A 50 46 20 25 29
43h DIMM ZONE
1 Temp
Actual_Reading (degrees C) = Raw_Data
3C 32 28 17 1A 1E
44h DIMM ZONE
2 Temp
Actual_Reading (degrees C) = Raw_Data
3C 32 28 17 1A 1E
45h PCH Temp Actual_Reading (degrees C) = Raw_Data
5A 50 46 17 1A 1E