Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guida Utente Pagina 76

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 931
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 75
Trap/EventID 4274
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
BAT1009
Message Write policy on
arg1
was changed to Write Back.
Arguments
arg1 =
controller name
Detailed
Description
The controller battery health has returned to normal.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
Trap/EventID 4275
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
BAT1010
Message Battery on
arg1
requires reconditioning. Initiate a learn cycle.
Arguments
arg1 =
Controller name
Detailed
Description
Battery is in warn only mode and requires reconditioning.
Recommended
Response Action
Start a learn cycle on the battery.
Category Storage
SubCategory BAT = Battery Event