Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guida Utente Pagina 778

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 931
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 777
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SWC8606
Message Quick Deploy Profile: Timeout exceeded while waiting for remote services ready on
Server
arg1
.
Arguments
arg1 =
server number
Detailed
Description
The target server never reported that remote services were ready.
Recommended
Response Action
Ensure that the server is operating properly on boot and Lifecycle Controller is enabled.
Category Audit
SubCategory SWC = Software Config
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SWC8607
Message Quick Deploy Profile: Start to apply profile "
arg1
" to server
arg2
.
Arguments
arg1 =
profile name
arg2 =
server number
Detailed
Description
The Quick Deploy of Profile process has started.
Recommended
Response Action
No response action is required
Category Audit
SubCategory SWC = Software Config
778
Vedere la pagina 777
1 2 ... 773 774 775 776 777 778 779 780 781 782 783 ... 930 931

Commenti su questo manuale

Nessun commento