Dell Chassis Management Controller Version 4.50 Guida Utente Pagina 29

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 428
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 28
time = 14:30dayofmonth =1
repeat = 5
applyreboot = 1
idracuser = racuser
To clear and display AutoUpdateScheduler parameter:
racadm autoupdatescheduler clear
Successfully cleared the Automatic Update (autoupdate)
feature settings
cd
Description
To change the current working object, use this command.
Synopsis
racadm> cd <object>
Input
racadm> cd <object>
Output To run object-related use the get or set commands.
Example
Example 1: To run all system-related get or set commands:
Input:[root@idrac-<username>]racadm> cd system
Output:
[root@idrac-<username>]system>
Example 2: To run all the power-related get or setcommands:
Input: [root@idrac-<username>]system> cd power
Output:
[root@idrac-<username>]power>
cd..
Description
To go back to the previous object, use this command.
Synopsis
racadm> cd..
Input
racadm> cd..
Output To traverse back to the previous object, use the command.
Example
Example 1: To traverse back from power to system object:
Input:[root@idrac-<username>]power> cd..
Output:
[root@idrac-<username>]system>
Example 2: To traverse back from system object to the prompt:
Input: [root@idrac-<username>]system> cd..
Output:
[root@idrac-<username>]racadm>
29
Vedere la pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 427 428

Commenti su questo manuale

Nessun commento