Dell Chassis Management Controller Version 4.50 Guida Utente Pagina 56

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 428
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 55
16 Enabled Not Present
idrac System Disabled
Display the current flex address setting for slot 1.
racadm getflexaddr -i 1
Slot-1 server presence = Present
Slot-1 flexaddress enabled = 1
<
Fabric> <Type> <Server-Assigned> <Chassis-Assigned>
slot1-A1 Gigabit Ethernet 00:1C:
23:CD:AC:D2(active
)
00:1E:C9:FF:E3:21
iSCSI 00:1C:
23:CD:AC:D3(active
)
00:1E:C9:FF:E3:22
slot1-A2 Gigabit Ethernet 00:1C:
23:CD:AC:D4(active
)
00:1E:C9:FF:E3:23
iSCSI 00:1C:
23:CD:AC:D5(active
)
00:1E:C9:FF:E3:24
slot1-B1 Gigabit Ethernet 00:1D:09:71:B3:60 00:1E:C9:FF:E3:25(
active)
iSCSI 00:1D:09:71:B3:61 00:1E:C9:FF:E3:26(
active)
slot1-B2 Gigabit Ethernet 00:1D:09:71:B3:62 00:1E:C9:FF:E3:27(
active)
iSCSI 00:1D:09:71:B3:63 00:1E:C9:FF:E3:28(
active)
slot1-C1 Fiber Channel 4 10:00:00:00:C9:63:
51:0E
20:01:00:1E:C9:FF:
E3:29(active)
slot1-C2 Fiber Channel 4 10:00:00:00:C9:63:
51:0D
20:02:00:1E:C9:FF:
E3:29(active)
getfanreqinfo
Description Displays fan speed request for servers and switches in percent (%).
This subcommand is applicable only for CMC.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getfanreqinfo
Input None
Output None