Dell OpenManage Server Administrator Version 5.0 Manuale Utente Pagina 47

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 248
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 46
omreport: Viewing System Status Using the Instrumentation Service 47
Server Administrator displays the following output:
Server Administrator reports values for the Redundancy Status and Redundancy Mode fields.
omreport chassis batteries
Use the omreport chassis batteries command to view battery properties.
omreport chassis bios
Use the omreport chassis bios command to view current BIOS information. When you type:
omreport chassis bios
Server Administrator displays a summary of your system’s BIOS information.
AC Failover Switch
AC Switch Redundancy
Redundancy Status : Full
Number of devices required for full
redundancy
:2
Redundancy Mode :
Redundancy Configuration : Input Source Line 1,
upon redundancy restoration, return to Line 1
AC Power Lines
Status : Ok
Location : AC Power Line 1
AC Present : Power Present
Active Source : Active
Status : Ok
Location : AC Power Line 2
AC Present : Power Present
Active Source : Not Active