Dell OpenManage Server Administrator Version 5.5 Guida Utente Pagina 122

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 238
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 121
122 Storage Management Message Reference
2126
contd.
If the disk is part of a
redundant virtual disk,
then any data residing on
the corrupt portion of
the disk will be reallocated
elsewhere in the
virtual disk.
2127 Background
initialization
(BGI)
started
OK /
Normal
Cause: BGI of a virtual disk
has started. This alert is for
informational purposes.
Action: None
Clear Alert
Status: 2130.
Related Alert
Number:
None.
LRA Number:
None.
1201
2128 BGI
cancelled
OK /
Normal
Cause: BGI of a virtual disk
has been cancelled. A user
or the firmware may have
stopped BGI.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1201
2129 BGI failed Critical /
Failure /
Error
Cause: BGI of a virtual disk
has failed.
Action: None
Clear Alert
Number:
None.
Related Alert
Number: 2340
LRA Number:
2081
1204
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vedere la pagina 121