22 Event Message Reference
1054 Temperature sensor detected
a failure value
Sensor location:
<Location
in chassis>
Chassis location:
<Name of
chassis>
Previous state was:
<State>
If sensor type is not
discrete:
Temperature sensor value (in
degrees Celsius):
<Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Error A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
exceeded its failure
threshold. The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.
1055 Temperature sensor detected
a non-recoverable value
Sensor location:
<Location
in chassis>
Chassis location:
<Name of
chassis>
Previous state was:
<State>
If sensor type is not
discrete:
Temperature sensor value (in
degrees Celsius):
<Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Error A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
detected an error from
which it cannot
recover. The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.
Table 2-2. Temperature Sensor Messages (continued)
Event
ID
Description Severity Cause