Dell OpenManage Server Administrator Version 5.5 Guida Utente Pagina 69

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 238
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 68
System Event Log Messages for IPMI Systems 69
Intrusion Events
The chassis intrusion messages are a security measure. Chassis intrusion
alerts are generated when the system's chassis is opened. Alerts are sent to
prevent unauthorized removal of parts from the chassis.
Table 3-11. Intrusion Events
Event Message Severity Cause
<Intrusion sensor
Name> sensor detected
an intrusion.
Critical This event is generated when the
intrusion sensor detects an intrusion.
<Intrusion sensor
Name> sensor returned
to normal state.
Information This event is generated when the
earlier intrusion has been corrected.
<Intrusion sensor
Name>
sensor intrusion
was asserted while
system was ON
Critical This event is generated when the
intrusion sensor detects an intrusion
while the system is on.
<Intrusion sensor
Name>
sensor intrusion
was asserted while
system was OFF
Critical This event is generated when the
intrusion sensor detects an intrusion
while the system is off.
Vedere la pagina 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 237 238

Commenti su questo manuale

Nessun commento