Dell OpenManage Server Administrator Version 6.1 Guida Utente Pagina 110

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 252
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 109
110 Storage Management Message Reference
2108 Smart
warning
Warning /
Non-critical
Cause: A disk has
received a SMART alert
(predictive failure).
The disk is likely to fail
in the near future.
Action: Replace the
disk that has received
the SMART alert. If the
physical disk is a
member of a
non-redundant virtual
disk, then back up the
data before replacing
the disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk will cause the
virtual disk to fail and
may cause data loss.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vedere la pagina 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 251 252

Commenti su questo manuale

Nessun commento