76 System Event Log Messages for IPMI Systems
Cable Interconnect Events
The cable interconnect messages are used for detecting errors in the hardware
cabling.
Battery Events
Table 3-15. Cable Interconnect Events
Description Severity Cause
Cable sensor <Name/
Location>
Configuration error was
asserted.
Critical This event is generated when
the cable is not connected or
is incorrectly connected.
Cable sensor <Name/
Location>
Connection was asserted.
Information This event is generated when
the earlier cable connection
error was corrected.
Table 3-16. Battery Events
Description Severity Cause
<Battery sensor Name/
Location>
Failed was asserted
Critical This event is generated when
the sensor detects a failed or
missing battery.
<Battery sensor Name/
Location>
Failed was deasserted
Information This event is generated when
the earlier failed battery was
corrected.
<Battery sensor Name/
Location>
is low was asserted
Warning This event is generated when
the sensor detects a low battery
condition.
<Battery sensor Name/
Location>
is low was deasserted
Information This event is generated when
the earlier low battery condition
was corrected.