Dell OpenManage Server Administrator Version 6.1 Guida Utente Pagina 85

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 252
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 84
Storage Management Message Reference 85
Table 4-4. Storage Management Messages
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
2048 Device failed Critical /
Failure / Error
Cause: A storage
component such as
a physical disk or an
enclosure has failed.
The failed component
may have been
identified by the
controller while
performing a task such
as a rescan or a check
consistency.
Action: Replace the
failed component.
You can identify which
disk has failed by
locating the disk that
has a red “X” for its
status. Perform a rescan
after replacing the
failed component.
Clear Alert
Number:
2121.
Related Alert
Number:
2095, 2201,
2203
LRA Number:
2051, 2061,
2071, 2081,
2091, 2101
754
804
854
904
954
1004
1054
1104
1154
1204
Vedere la pagina 84