Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guida Utente Pagina 100

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 292
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 99
100 Storage Management Message Reference
2108 SMART
warning
Warning /
Non-critical
Cause: A disk has
received a SMART alert
(predictive failure).
The disk is likely to fail
in the near future.
Action: Replace the
disk that has received
the SMART alert. If the
physical disk is a
member of a
non-redundant virtual
disk, then back up the
data before replacing
the disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk causes the virtual
disk to fail and may
cause data loss.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2070
903
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vedere la pagina 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 ... 291 292

Commenti su questo manuale

Nessun commento