248 System Event Log Messages for IPMI Systems
<Sensor Name/Location>
temperature sensor
returned to warning state
<Reading>.
Warning Temperature of the backplane
board, system board, or the carrier
in the specified system <Sensor
Name/Location> returned from
critical state to non-critical state.
<Sensor Name/Location>
temperature sensor
returned to normal state
<Reading>.
Information Temperature of the backplane
board, system board, or the carrier
in the specified system <Sensor
Name/Location> returned to
normal operating range.
The <Sensor Name/
Location> temperature is
less than the lower
warning threshold.
Warning Temperature of the backplane,
system board, system inlet, or the
carrier in the specified system
<Sensor Name/Location>
entered into non-critical state.
The <Sensor Name/
Location> temperature is
less than the lower
critical threshold.
Critical Temperature of the backplane,
system board, system inlet, or the
carrier in the specified system
<Sensor Name/Location>
entered into critical state.
The <Sensor Name/
Location> temperature is
greater than the upper
warning threshold.
Warning Temperature of the backplane,
system board, system inlet, or the
carrier in the specified system
<Sensor Name/Location>
entered into non-critical state.
The <Sensor Name/
Location> temperature is
greater than the upper
critical threshold.
Critical Temperature of the backplane,
system board, system inlet, or the
carrier in the specified system
<Sensor Name/Location>
entered into critical state.
The <Sensor Name/
Location> temperature is
outside of range.
Critical Temperature of the backplane,
system board, system inlet, or the
carrier in the specified system
<Sensor Name/Location> is
outside of normal operating
range.
Table 4-1. Temperature Sensor Events
(continued)
Event Message Severity Cause
Vedere la pagina 247