Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guida Utente Pagina 85

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 292
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 84
Storage Management Message Reference 85
2081
contd.
Software RAID:
•Perform a backup
with the Verify
option.
If the file backup
fails, try to restore the
failed file from a
previous backup.
When the backup
with the Verify option
is complete without
any errors, delete the
Virtual Disk.
Recreate a new
Virtual Disk with new
drives.
Restore the data from
backup.
2082 Virtual disk
rebuild failed
Critical /
Failure / Error
Cause: A physical disk
included in the virtual
disk has failed or is not
functioning. A user may
also have cancelled
the rebuild.
Action: Replace the
failed or non-functional
disk. You can identify a
disk that has failed by
locating the disk that
has a red “X” for its
status. Restart the
virtual disk rebuild.
Clear Alert
Number:
None
Related
Alert
Number:
2048
LRA
Number:
2081
1204
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Vedere la pagina 84
1 2 ... 80 81 82 83 84 85 86 87 88 89 90 ... 291 292

Commenti su questo manuale