Storage Management Message Reference 167
2265 A device is in
an unknown
state.
Warning /
Non-critical
Cause: The controller
cannot communicate
with a device. The state
of the device cannot be
determined. There may
be a bad or loose cable.
The system may also be
experiencing problems
with the application
programming interface
(API). There could also
be a problem with the
driver or firmware.
Action: Check the
cables. Check if the
controller has a
supported version of the
driver and firmware.
You can download the
current version of the
driver and firmware
from support.dell.com.
Rebooting the system
may also resolve this
problem.
Clear Alert:
None
Related
Alert
Number:
2048, 2050
LRA
Number:
2050, 2060,
2070, 2080,
2090, 2100
753
803
853
903
953
1003
1053
1103
1153
1203
Table 3-4. Storage Management Messages