Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Guida Utente Pagina 34

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 292
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 33
34 Server Management Messages
1203 Current sensor detected a
warning value
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading> OR
Current sensor value (in
Watts): <Reading>
If sensor type is discrete:
Discrete current state: <State>
Warning A current sensor
in the specified
system exceeded
its warning
threshold.
The sensor
location, chassis
location, previous
state, and current
sensor value
are provided.
1204 Current sensor detected a
failure value
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading> OR
Current sensor value (in
Watts): <Reading>
If sensor type is discrete:
Discrete current state: <State>
Error A current sensor
in the specified
system exceeded
its failure
threshold.
The sensor
location, chassis
location, previous
state, and current
sensor value
are provided.
Table 2-5. Current Sensor Messages
(continued)
Event
ID
Description Severity Cause
Vedere la pagina 33